Best practices for opportunistic charging of lithium-ion batteries

2021/05/13 | Lithium Forklift Battery | 2

Opportunity charging is a practice applicable to both lead acid and lithium-ion (Li-ion) batteries for motive power systems and especially useful for materials handling equipment.  These practices can be applied to all classes of handling equipment - from small pallet jacks to four-wheel forklifts and large turret trucks.


Charging lead acid batteries


Different lead acid battery types are available for motive power including the Thin Pure Plate Lead (TPPL), Absorbed Glass Matt (AGM) and the widely used, most common Flooded Lead Acid (FLA). For optimal cycle and calendar life of FLA batteries, manufacturers recommend that the daily cycle for batteries consist of:


1) using and discharging the batteries, typically over an eight-hour shift;


2) 8-10 hours of conventional charging at a C/5 rate (i.e. ~20 Amps per every 100 Amp-Hours);


3) resting for an eight-hour cool-down period.


Additionally, it is critical to equalise the battery on a weekly basis: charging the battery to 100% state of charge and reducing the build-up of sulphates. This conventional charge/discharge regimen is reinforced by FLA battery manufacturers through their warranties; thus each battery experiences one full charge and discharge cycle per day. Note that FLA batteries can be opportunity charged (typically 25 Amps per 100 Amp-Hour or C/4 rate) and fast charged (typically up to 50 Amps per 100 Amp-Hour or C/2 rate), but these unconventional FLA charge regimens shorten or violate the manufacturer warranties.


If an enterprise follows guidelines from the manufacturer, then they can expect to receive 500-1,000 cycles from their FLA batteries before they start to experience permanent capacity fade. The implication of this recommended charge regimen is that equipment used on a single shift may need one or two batteries for each vehicle. If the enterprise operates a multi-shift operation, then more than one battery is definitely required per vehicle. So, at a minimum, multi-shift operations dictate a battery swap when the shift changes.


Charging Li-ion batteries


Li-ion batteries are preferably charged using a constant current/constant voltage (CC/CV) charge regimen, but most materials handling equipment batteries are designed to accept both CC/CV and FLA charge regimens. One common characteristic of all Li-ion batteries is that, regardless of the state of charge of the battery when connected to the charger, the battery will efficiently accept the power and increase its state of charge. Whether the battery has been connected to the charger for 15 minutes or two hours, that battery can be immediately discharged and used by the equipment as there is no need to cool or rest a Li-ion battery after charging.


Meet The NEW BSLBATT LIthium


The Li-ion cell chemistry has numerous chemical variants. Lithium Iron Phosphate (LFP) chemistry is the predominant chemistry used to power materials handling equipment. LFP chemistry is differentiated from its Li-ion cousins on several dimensions, including:


1) exceptionally long cycle life (2,000 - 4,000 cycles to reach 80% of the original capacity);


2) Along with opportunity charging capability, Li-Ion batteries have much faster charging times than their older, lead-acid batteries counterparts.


3) Li-Ion batteries give you more consistent, stable power when in use. Unlike lead-acid types, the voltage level and power availability remain at a higher, more even level. Lead-acid technology loses both voltage level and power in a downward curve, from the time you plug in the battery to the final job. This can be particularly important in cold storage or freezer applications. Cold is the sworn enemy of lead-acid batteries. You will lose between 30-50% of available capacity in cold or freezing applications with lead-acid.


4) Li-Ion batteries are virtually maintenance-free. Lead-acid batteries need to be cleaned, watered and equalized on a regular basis. Li-Ion batteries don’t need these operations. And there’s no crusty caustic build-up to remove.


5) Li-Ion batteries are designed for opportunity charging. In other words, you can plug them into a charger anytime the forklift isn’t in use. This saves time by eliminating the need for labor-intensive battery swaps.


The long cycle life means an LFP battery can be installed and remain in the equipment until it is retired (i.e. no battery swaps for the equipment life). More importantly, since LFP chemistry can accommodate high power delivered to and from the battery, a depleted LFP battery can accept a full charge in one hour. This charge does not need to be delivered in one charging session. Rather, it can be delivered throughout the shift when the operator has down-time (for example, a break or lunch). Since LFP batteries can accept partial charges between use and a depleted battery can be charged within one hour, Li-ion is the optimal chemistry for opportunity charging.


Beyond opportunity charging, some secondary benefits of adopting Li-ion batteries to power your fleet include the release of warehouse floor space, the elimination of battery handling and changing equipment, and the reduction of personnel affiliated with the charging process. Additionally, operators can eliminate the cross-area travel time from their normal work areas to the battery room to change out batteries. Finally, the potentially hazardous task of swapping heavy batteries is not necessary, thus minimising employee injuries.


Lithium battery forklift factory

The Myth of a Necessary 1C Charging Rate Revealed

What is an important consideration is charging times during normal forklift operations. The charging rate is designated by C, which stands for charge current, not charge voltage. A battery that can be charged at 1C will go from 0% charge to fully charged in one hour. NMC batteries achieve this charging rate easily, as many manufacturers and sales reps will inform you. In fact, that’s one of the main selling points they’ll tout during their pitch. An LFP Li-Ion battery, on the other hand, normally has a charging rate of between .5 to .8 C. What this means is that the battery will charge from 0% to 100% in about two hours at .5C and perhaps closer to 1-1/2 hours at .8C. That seems significantly slower, a potential downside to LFP batteries. So obviously, the sales rep’s biggest draw is that the NMC will charge completely in half the time of the LFP Li-Ion battery. The cost to do that may be slightly higher, both for the battery and the accompanying heavy-duty hardware required. But the time saved for the entire charge cycle makes up for it, right? Not necessarily. The need for a zero to 100% charge in 60 minutes sidesteps one of the main benefits of Li-Ion batteries as a whole: opportunity charging. Think about it for a minute. When will you ever completely drain your battery? If you’re seeing that happen, you’ve likely got a personnel problem, not a battery issue. One of your drivers is not taking advantage of opportunity charging. The fact is that if opportunity charging is used, you’ll rarely get more than a 20-30% power drain, even in freezers and cold storage operations. Therefore, the higher charging rate of 1C for an NMC Li-Ion battery is really a non-issue. It’s just an exaggerated selling point with no real tangible benefit. You’re being sold a tractor/trailer rig … when a box truck or van will do the job. But there’s one final and important nail to hammer in the coffin of the 1C myth. Safety.

Best practices to exploit opportunity charging

Listed below are the guidelines that BSLBATT Lithium has developed to assist our customers in maximising their return on investment in Li-ion batteries and charging infrastructure. Opportunity charging has a multiplier effect on the positive return for adopting Li-ion batteries.


1. Understand the existing operational workflow of the operators/equipment/batteries to assess the available time per shift to connect to a charger. This can be established through a power study where the operator/equipment/battery activity is monitored for up to four weeks, and worst-case usage models should not be ignored. Based on the data, one can determine whether there are adequate opportunities for ad hoc (eg. coffee break) or scheduled (eg. lunch) charging throughout the shift. If there is no down-time for the equipment throughout the shift, then the batteries will need to be charged for an hour before the shift. Or, the operator's existing work flow can be modified so that there is some down-time made available for opportunity charging the equipment.


2. Single-shift vs. multi-shift operations can determine the value of opportunity charging for an enterprise. If the enterprise operates a single-shift operation, a fully charged Li-ion (or FLA) battery should power that vehicle through the shift. However, when a second (or third) shift is needed, then opportunity charging can be used to recharge that integrated battery in increments and ensure that the equipment is powered through all the shifts.


3. Rather than charging FLA batteries in a centralised battery maintenance room, the enterprise can distribute the Li-ion charging stations near break rooms and heavy work areas. This will encourage and enable operators to charge their equipment when the operators have down-time or are not using their equipment. Decentralised charging stations eliminate the operators' travel time from their work area to the battery maintenance room as well.


4. Assess existing FLA chargers to determine if they are compatible with the Li-ion batteries. There are some charging parameters, such as voltage limits, that need to be aligned between the battery and charger. But most FLA chargers are typically compatible with Li-Ion batteries, enabling the use of the existing charging infrastructure for opportunity charging.


5. Assess the power output of the existing FLA and Li-ion charging infrastructure. As mentioned earlier, the conventional FLA battery charge regimen is a C/5 rate over an eight-hour period. With opportunity charging, the Li-ion battery should be charged throughout the shift at a 1 C rate for a total accumulated time of one hour. The implication is the power rating on the charger must be much higher when opportunity charging. As an example, a 48 Volt 500 Amp-Hour FLA battery could be charged with a 5 kW charger over an eight hour period, while a similarly-sized Li-ion battery would require a 25 kW charger for a one hour period.


6. Consider a multi-voltage battery if opportunity charging is desired but there is not adequate down-time within a shift. A multi-voltage battery has a power switching fabric within the battery electronics. The charger's charge voltage is set at twice the equipment's operating voltage, and the battery electronics then steps down the received power to the equipment's operating voltage. The charger delivers twice the amount of power when charging at twice the voltage, therefore the charge time is reduced by 50%. Multi-voltage battery options are available in 24 v (24/48), 36 v (36/72) and 48 v (48/96) battery configurations.


7. Consider the equipment/charger ratio. The best case for operators is a 1:1 ratio, so all operators can take their lunch together and each piece of equipment can be charged during this down-time. If the enterprise can stagger coffee/lunch breaks or run the fleet between 50-100% utilisation, then they can reduce this ratio down to 2:1 and still ensure that all equipment has unfettered access to the local charger.


8. Assess your operators' behaviour after you have introduced opportunity charging. Some Li-ion batteries have embedded Internet of Things (IoT) computing, WiFi transceivers and cloud-based applications so the enterprise can remotely monitor their operators' adoption and effectiveness with opportunity charging. One simple measure is monitoring the state of charge of each piece of equipment/battery throughout the day. Any operators/equipment consistently operating in the 5-20% state of charge range may need some retraining on opportunity charging.

About the Author

Lithium Forklift Battery

Since 2012, served as chief engineer in our company, won a “Hefei gold worker" and another honorary title, its lead type low-temperature water system 76 Ah aluminum shell lithium iron phosphate power battery won the fifth worker in Hefei title of “Excellent" technology innovation achievements, Leading the development of ternary aluminum shell, water system lithium iron phosphate aluminum shell, water system lithium iron phosphate plastic shell and other products.